2000 Noise Figure Results

2000 Noise Figure (NF) Results

Tested in Winnipeg, Manitoba, Canada - July 21, 2000

 

50 MHzCallDesign DeviceNF (dB)Gain (dB)
N0AKCDEMI 0.5618.7
WA5VJBWA5VJBMGF18010.1621.9
N0AKCWA5VJB DEADDEAD
 
144 MHzCallDesign DeviceNF (dB)Gain (dB)
KA0RYTCAVITYATF331430.1330.2
K5JLL/C INPUTMGF18010.1523.7
WD5AGOAGO L/C INPUTATF331430.1723.75
VE7BQHL/C INPUTMGF18010.1920.6
VE7BQHCAVITYATF331430.2125.4
WD5AGOCAVITYATF331430.2421.9
W7CS#2MGF13020.2923.7
W7CS#5MGF13020.3423.2
W7CS#4MGF13020.3524.5
W7CS#3MGF13020.2724.1
K6LEW MGF13020.5220
W7CS#1MGF13020.5824
VE3AXL/C INPUTMGF13020.99.6
K0AWUARRMGF13020.9719.5
KA2KQMMMIC?? 5.4723.32
 
222 MHzCallDesign DeviceNF (dB)Gain (dB)
WA4NJP MGF13020.2521.7
WA4NJPLCMGF13020.321.1
KA0Y MGF14020.3122.3
WB0OAJ MGF11000.4618.7
VE3AX MGF12000.4620.3
K6LEW MGF13020.5123.3
 
432 MHzCall DesignDeviceNF (dB)Gain (dB)
KA0RYTRYT CAVITYATF101360.1226.94
K5JLCAVITYATF101360.1820.75
K5JLCAVITYATF101360.2919.4
WD5AGOL/CATF341430.318.22
N0ISCAVITYMGF13020.320.5
KA0RYTCAVITYATF101360.325.5
WD5AGOAGOATF341430.3219.7
K0AWUARRMGF14020.7917.5
WB0OAJL/CMGF11000.8315.4
KA0Y1980 Vintage LNAD4320.9315.6
K6LEW MGF13021.0214.9
KA0YL/CMGF13021.1615.8
KA0Y MGF14022.222.2
KB0OBT MGF14022.759.1
 
902 MHzCall DesignDeviceNF (dB)Gain (dB)
W0FMSDEMI XVTRATF101361.4520
KA2KQMA-965Avantek3.119.4
 
1296 MHzCall DesignDeviceNF (dB)Gain (dB)
W7QX(1296-39) 0.2223.03
KA0YKB2AHFHX35LG0.2219.53
K5JLW7CNKATF360770.2218.43
WA4NJPAGO 0.2820.18
VE3AXAGO 0.3215.22
W7CSAGO1 0.4630.14
W7CSAGO3 0.5728.57
AL7EB1420 MHz LNA 0.630.51
W7CSAGO2 0.6814.14
W7QX2 STAGE0.7610.63
W7QX1296-2 0.814.31
AL7EBDEM xvrtr 1.1912.84
KA2KQMA-965 0.8214.69
KA0YParabolic xvrtr 1.1912.84
 
1420 MHzCall DesignDeviceNF (dB)Gain (dB)
AL7EBLNA 0.331.08
AL7EBconverter 1.8836.7
 
2304 MHzCall DesignDeviceNF (dB)Gain (dB)
N0ISDEMI 0.3518.21
KA2KQMA-965Avantek3.0318.94
KA2KQMH783 AMPAvantek3.518.5
N2CEIDEMI 2400 MHz Converter 0.821.6
 
10368 MHzCall DesignDeviceNF (dB)Gain (dB)
AL7EBDB6NT 0.7823.38
K1RQGConverted DBS LNA 1.0623.78

Tested by W5LUA, N5QGH, WA8WZG, KA0RYT, N2CEI
Equipment supplied by Agilent Technologies by W5LUA and VA6BB (Bohdan Berestiansky)
HP346A Noise Source, Measurement Accuracy of system according to HP is +/- 0.2 dB!